Home  /  Ceilings  /  Glass-fibre acoustic ceiling

Glass-fibre acoustic ceiling panels

Noise in a ward is treated as a finishes problem, and it is not: it is a mass-and-absorption problem, and a hard ceiling leaves nothing in the build-up to absorb it. We supply a glass-fibre panel that absorbs at NRC ≥ 0.90 while holding Class A fire classification and an antibacterial face.

NRC ≥ 0.90 to EN ISO 354 Class A to EN 13501-1 CE marking · SGS · Korean fire certification

What the panel is, and what it is not

It is a glass-fibre board at 100–150 kg/m³, finished as a ceiling panel rather than a wall or duct liner. Density in that band gives the board enough rigidity to stay flat across a grid bay while keeping the open structure that does the absorbing.

It is not a wipe-down plastic ceiling. Where the requirement is direct water spray, aggressive disinfectant and a sealed non-porous face, our GRP antibacterial panel is the right product and we will say so rather than sell this one into the wrong room.

Two properties it does hold: dimensional stability at high humidity — the panel is rated stable at RH 99 — and a face that is antibacterial above 99.99% against E. coli and S. aureus to GB/T 31402, with anti-mould Grade 0 to GJB 150.10A.

Test data

Every figure below carries the standard it was tested to. Where a figure is not on a report, it is not in the table.

ProductParameterResultTest standard
Glass-fibre acoustic ceiling panelSound absorptionNRC ≥ 0.90EN ISO 354 / GB/T 20247
Glass-fibre acoustic ceiling panelFire classificationClass AEN 13501-1 / GB 8624
Glass-fibre acoustic ceiling panelAntibacterial, E. coli & S. aureus> 99.99%GB/T 31402
Glass-fibre acoustic ceiling panelAnti-mouldGrade 0GJB 150.10A
Glass-fibre acoustic ceiling panelMoisture resistanceStable at RH 99Report on request
Glass-fibre acoustic ceiling panelDensity100–150 kg/m³Report on request
Glass-fibre acoustic ceiling panelEnvironmental labelChina 10-Ring eco-labelChina environmental labelling programme
On the absorption figure: NRC is a laboratory number, and on site it depends on the void depth and the grid layout. The report states the mounting condition it was measured on, and that condition is what you should compare against your own ceiling void.

Against mineral fibre and gypsum

The three ceilings below are the ones specified into the same rooms, so the comparison is worth putting in front of a value-engineering review. The alternative within our own range is the GRP antibacterial ceiling.

Glass-fibre acousticMineral fibre (typical)Gypsum board (typical)
Sound absorptionNRC ≥ 0.90Moderate to goodLow
FireClass AVaries by productBoard and framing vary
HumidityStable at RH 99Absorbs, then sagsSoftens, crumbles
Antibacterial> 99.99%Add-on coatings onlyNone inherent
CleaningWipe and damp mopFace damaged by scrubbingRepaint cycle

The comparison that decides a hospital ceiling is not the panel alone. A mineral fibre ceiling that sags above a live ward is replaced with containment, night shifts and patients moved; that cost never appears on the panel line of the quotation, but it is paid inside the same ten years.

Certification, stated plainly

This is the only range we supply with CE marking. The classification behind it is Class A to EN 13501-1, and the file holds SGS reports and Korean fire certification alongside the declaration of performance.

The same policy applies in the other direction: our GRP antibacterial ceiling and our medical clean wall panel do not carry CE marking, and we say that before it is written into a specification rather than after. What those ranges do carry is their own fire, antibacterial and physical test reports, issued in English.

If a consultant needs the declaration and the classification report to close a submittal, ask at tender stage. They are released against a project reference with the quotation.

Where it is specified

Absorption earns its cost in rooms where speech, alarms and trolley noise have nowhere to go:

  • Ward corridors and bed bays, where speech privacy is the recurring complaint
  • Nursing stations and waiting areas
  • Imaging and ultrasound rooms, where hard surfaces ring
  • Mental health units, where a fixed, cleanable ceiling is preferred
  • Consulting and treatment rooms
  • Lecture theatres and seminar rooms in teaching hospitals
  • Open-plan administrative floors inside the hospital block

Humidity is the usual objection. Rated stable at RH 99, the panel does not need substituting on moisture grounds in a humid plant room or a therapy pool hall — but check the cleaning regime first, because that is where the choice between this panel and GRP actually changes.

FAQ

What NRC does the panel reach, and on what mounting?

NRC ≥ 0.90 to EN ISO 354 and GB/T 20247. The figure is measured on a defined mounting, so ask for the mounting condition with the report: a deep void over a sealed plenum does not behave like a shallow one, and the report states which was tested.

Can it go into wet areas instead of a GRP ceiling?

It is stable at RH 99 and Grade 0 anti-mould to GJB 150.10A, which covers humid air and condensation. It is not a hose-down panel: where walls and ceilings are washed with disinfectant under pressure, specify GRP.

Do you release the CE declaration and reports before an order?

Yes, in English, at submittal stage and against a project reference. If your consultant holds a clause we have not been tested against, send the clause and we answer it in writing rather than with a brochure.

Send the ceiling area and the acoustic target.

We return the NRC report, the fire classification and a CAD detail of the grid for your submittal.

Request the specification pack