Home  /  Products  /  Ceiling panels

GRP and glass-fibre ceiling panels

Ceiling selection in a hospital or a laboratory comes down to one question: is this room’s problem moisture, or noise? Our two ranges answer those separately, and we would rather you specified the right one than bought both.

A2-S2,d0,t0 to EN 13501-1 NRC ≥ 0.90 to EN ISO 354 0.3% water absorption

Two ranges, two jobs

The GRP antibacterial panel is a rigid glass-fibre reinforced polymer panel. It is specified where the room gets wet, gets cleaned hard, or both: 0.3% water absorption, resistance to strong acids and alkalis, Barcol 86 HBa surface hardness, and A2-S2,d0,t0 to EN 13501-1.

The glass-fibre acoustic panel is a porous absorber. It is specified where the problem is sound: NRC ≥ 0.90 to EN ISO 354, Class A to EN 13501-1 / GB 8624, antibacterial performance above 99.99% to GB/T 31402, and anti-mould Grade 0 to GJB 150.10A.

The two properties fight each other: a dense sealed panel reflects sound back into the room, and an open absorbing panel is the one that takes on moisture. No single ceiling is good at both, which is why we make two.

Test data

Values carry their standard. Where the column reads “report on request”, the report travels with the quotation.

ProductParameterResultTest standard
GRP antibacterial ceilingFire classificationA2-S2,d0,t0EN 13501-1
GRP antibacterial ceilingWater absorption0.3%Manufacturer test
GRP antibacterial ceilingAntibacterial / anti-mould99.5% · class I / class 0JIS Z 2801
GRP antibacterial ceilingSurface hardnessBarcol 86 HBaManufacturer test
GRP antibacterial ceilingChemical resistanceStrong acids and alkalisManufacturer test
Glass-fibre acoustic ceilingSound absorptionNRC ≥ 0.90EN ISO 354 / GB/T 20247
Glass-fibre acoustic ceilingFire classificationClass AEN 13501-1 / GB 8624
Glass-fibre acoustic ceilingAntibacterial (E. coli, S. aureus)> 99.99%GB/T 31402
Glass-fibre acoustic ceilingAnti-mouldGrade 0GJB 150.10A
Glass-fibre acoustic ceilingMoistureStable at RH 99Manufacturer test
Glass-fibre acoustic ceilingDensity100–150 kg/m³Manufacturer test
On European marking: CE marking, SGS reports and Korean fire certification are held for the glass-fibre acoustic range. Fire, acoustic, antibacterial and hardness data for the GRP range come with the test reports themselves — check which range your clause names before tender.

Choosing between them

Read the room’s dominant failure mode, not the ceiling’s marketing. A ward where noise travels between bays needs absorption; a wash-down room where a ceiling sags after two years needs a sealed, low-absorption face.

GRP antibacterialGlass-fibre acousticMineral fibre (typical)Gypsum board (typical)
Primary driverMoisture, cleaningNoiseCostFlat finish
FireA2-S2,d0,t0Class AVaries by productBoard and framing vary
Sound absorptionNot the purposeNRC ≥ 0.90Moderate to goodLow
Water absorption0.3%Stable at RH 99Absorbs, sagsSoftens, crumbles
Antibacterial99.5%> 99.99%Coatings onlyNone inherent
DemountableYes, repeatedlyYesUsually single useNo
Dingborui · moisture

GRP antibacterial ceiling panels

A2-S2,d0,t0, 0.3% water absorption, 99.5% antibacterial to JIS Z 2801, concealed triangular grid.

Open the range →
Dingborui · acoustics

Glass-fibre acoustic ceiling panels

NRC ≥ 0.90 to EN ISO 354, Class A to EN 13501-1, anti-mould Grade 0 to GJB 150.10A.

Open the range →

Where each one belongs

Specify GRP where the room is wet or cleaned hard

  • Operating theatres and procedure rooms, after wash-down between cases
  • Clean corridors, utility rooms and sterile service areas
  • Pharmacy, laboratories and rooms where spillage is part of the process
  • Physiotherapy and hydrotherapy rooms held at high humidity
  • Any ceiling void that will be opened repeatedly for valves, dampers and detectors

Specify glass-fibre acoustic where the room is noisy

  • Inpatient wards and bay divisions, where speech privacy matters
  • Consulting rooms, waiting areas and nurse stations
  • Imaging and diagnostic rooms
  • Mental health and rehabilitation units
  • Education, sports halls and commercial interiors using the same system

FAQ

Can both ranges be used in the same building?

Yes, and most hospital projects do exactly that: acoustic panels where speech privacy matters, GRP where cleaning is aggressive or humidity uncontrolled. Both are demountable, so the plane stays consistent down a corridor.

Which range carries European marking?

The glass-fibre acoustic range holds CE marking, with SGS reports and Korean fire certification. The GRP range ships with fire, antibacterial, hardness and chemical-resistance reports. If your clause names European marking, write it against the acoustic range.

What is the minimum order, and can I get samples?

MOQ is quoted per project, since it depends on panel mix and thickness. Samples go out with cut sections, so your team sees the build-up rather than the face alone.

Send the room list, marked up by range

GRP or acoustic per room, with the report.

Request the specification pack